Home/Sample Deliverables
Sample deliverablesSee the standard of the work.
Every engagement produces documents that outlast it. The examples below show the structure, the level of detail and the standard of evidence you should expect — the architecture assessment, the findings register, the current-state and target-state diagrams, the failure-mode matrix, the remediation roadmap, the implementation and rollback plan, the operational runbook and the executive summary.
These examples are synthetic. They are written against an invented reference environment created for this page. No client, no client environment and no client result appears anywhere on this site. Nothing here is a redacted version of real work — work produced under an engagement belongs to the client who commissioned it and is not republished in any form.
An invented estate, built to be ordinary.
The examples below all describe the same fictional environment. It was designed to look like the kind of estate this work is usually commissioned on — large enough to have crossed several teams, old enough to have accumulated exceptions.
| Domain | Composition |
|---|---|
| Sites | Two data centers in an active/standby arrangement, fourteen branch locations, one manufacturing site with its own OT segment |
| Perimeter | Palo Alto firewall pairs at both data centers and at the internet edge, with a rulebase accumulated over roughly nine years |
| Application delivery | F5 LTM pairs fronting three business-critical applications, one of which terminates TLS twice |
| Access control | Cisco ISE for wired and wireless authentication, with a legacy MAB exception list nobody currently owns |
| WAN | Dual-carrier MPLS with an SD-WAN overlay part-deployed across the branch estate |
| Cloud | One AWS region, two production VPCs, a transit gateway and a centralized inspection VPC added eighteen months ago |
Eight documents, and what each one is for.
Which of these you receive depends on the engagement. An assessment produces the first five. Work that continues into remediation and implementation produces all eight.
Architecture assessment
The narrative document. What the environment is, how it actually behaves, where the design and the running state have separated, and what that costs in risk. Written to be read by an architect and skimmed by a director.
Findings and risk register
Every finding as a numbered row with a stated evidence basis, so each one can be argued with. Nothing enters the register on the strength of an opinion or a diagram.
Current-state and target-state diagrams
Drawn from the running configuration, not from the existing documentation. The current-state set is usually the first accurate picture of the environment anyone has held in years.
Failure-mode validation matrix
Each failure scenario, what the design says should happen, what was observed when it was exercised, and whether those two agree. Scenarios that could not be safely exercised are marked as untested rather than assumed.
Executive summary
Two pages for the people who authorize the budget. The risks in business terms, the decisions required, and what happens if none of them are taken.
Remediation roadmap
Findings sequenced into work that can actually be scheduled — grouped by dependency and by change window, not by severity alone. A critical finding that cannot be fixed before a prerequisite is sequenced behind it.
Implementation and rollback plan
Per change: the steps, the verification at each step, the point of no return, and the rollback that has been thought through before the window opens rather than during it.
Operational runbook
Written for the engineer who was not part of the project and is holding the pager at two in the morning. Procedures, expected output, and what to do when the output is not what was expected.
Every finding carries its evidence.
The evidence basis column is the part that matters. It is what separates a finding from an assertion, and it is what lets your team disagree with a specific row rather than with the report as a whole.
| ID | Finding | Domain | Risk | Evidence basis |
|---|---|---|---|---|
| F-014 | Return traffic for two VPC workloads bypasses the inspection VPC entirely | Cloud | High | Transit gateway route tables and a bidirectional flow capture taken at both ends |
| F-021 | Standby data center firewall pair holds a rulebase eleven revisions behind the active pair | Security | High | Configuration diff across both pairs, taken from the running configuration |
| F-027 | One application's failover depends on a persistence profile that does not exist on the standby F5 pair | Application delivery | High | Object-level comparison of both pairs, confirmed against the application's session behavior |
| F-033 | MAB exception list contains forty-one entries with no owner and no documented purpose | Access control | Medium | ISE endpoint identity group export cross-referenced against the asset register |
| F-038 | Six branch sites present as SD-WAN-enabled but still route production traffic over MPLS only | WAN | Medium | Overlay control-plane state compared against per-site forwarding tables |
Risk is stated, never scored into a single number. A composite score hides the reasoning that produced it. Each row carries its own risk statement so it can be weighed against your own priorities rather than against a formula.
What the design says, against what the environment did.
Resiliency is the area where documentation and reality separate most often, because the design is written once and the environment changes continuously. The matrix records what was actually exercised — and is explicit about what was not.
| Scenario | Expected behavior | Observed | Result |
|---|---|---|---|
| Active data center firewall pair fails over | Sessions preserved, no application impact | Sessions preserved; two applications reauthenticated because the standby pair holds an older rulebase | Partial |
| Primary carrier circuit loss at a branch | Traffic moves to the secondary carrier within seconds | Failover occurred as designed at eight of fourteen sites | Partial |
| F5 pair failover for the order-entry application | Persistence maintained, users unaffected | Persistence lost; users returned to login | Failed |
| Loss of the AWS transit gateway attachment | Traffic reroutes through the secondary attachment | Not exercised — no maintenance window available during the engagement | Untested |
| ISE policy node loss | Authentication continues against the secondary node | Authentication continued as designed | Passed |
Untested is a result, not a gap in the report. An engagement that quietly reports every scenario as passing is describing the design, not the environment. Where a scenario cannot be safely exercised, it is recorded as untested and carried into the roadmap as work still to be done.
Written for the engineer who was not in the project.
A runbook that only makes sense to the person who wrote it has failed. Each procedure states the trigger, the steps, the output to expect at each step, and what to do when the output differs.
Procedure 4.2 — Validate inspection path after a transit gateway route change. Run this after any change to transit gateway route tables, inspection VPC routing or the security VPC attachment — and as the final verification step of any cloud connectivity change window.
Confirm propagated routes in each spoke route table
Expected: the propagated set matches the documented target state exactly. Any additional route is a finding, not a variation.
Initiate a test flow from a workload in each production VPC
Expected: the flow completes to an external destination. Record the source, destination and timestamp.
Confirm the flow appears in the inspection firewall session table
Expected: one session, visible in both directions. A session visible in one direction only is the failure this procedure exists to catch.
Confirm the return path traverses the same inspection point
Expected: outbound and return traverse the same firewall. If they do not, stop — see below.
Retain the captures with the change record
Expected: session identifiers and both captures attached to the change, so the next engineer can compare against a known-good baseline.
If the return path does not traverse inspection, do not close the change window. Asymmetry here is the failure mode recorded as F-014, and it will not present as an outage. It presents as traffic leaving the environment uninspected, which nobody notices until somebody audits for it.
Every procedure carries the same six parts.
- 01The trigger that makes it necessary
- 02The steps, in the order they must be taken
- 03The output expected at each step
- 04The action when the output differs
- 05The point at which to stop and escalate
- 06The related finding, where one exists
No client work appears here, in any form.
Documents produced during an engagement belong to the client who commissioned them. They are not republished, not repurposed as marketing, and not shown to other prospects in redacted form. Redaction removes names; it does not remove an environment's fingerprint, and a prospective client who sees another client's architecture on this page learns exactly what would happen to theirs.
So the examples above are invented. The structure, the level of detail and the standard of evidence are real and are what you would receive. The environment they describe does not exist.
Want to see this against your own environment?
A short conversation establishes whether an assessment is the right starting point, and which one. There is no charge for it and no obligation attached to it.