Data Center · self-assessmentWould your data-center failover actually work?
Sixteen questions that establish whether your redundancy is a tested capability or a design-time assumption that nobody has revisited.
Resiliency degrades quietly. A link is added, a VLAN is stretched, a device is replaced with a slightly different model, a peer link is reconfigured during an incident and never reverted. Each change is reasonable on its own. Together they move the actual failure behavior away from the documented failure behavior, and the gap is usually discovered during the failure.
Run these in a room with your fabric team. The useful signal is not the answers — it is how many of them produce a pause.
How to use this. Go through the 16 questions with the team who run the environment. For each one, mark it only if somebody can answer it from evidence today — not from memory, not from a diagram, and not from what was true at build time. Count the ones you cannot. That number is the result.
Topology and design intent
-
01
Can somebody produce the current physical and logical topology from the devices, rather than from a diagram file?
If the answer is the diagram, you are testing the diagram, not the fabric.
-
02
Where is the spanning-tree root for each VLAN, and was that placement chosen or inherited?
-
03
Which links are in a port channel, and do the negotiated speeds match what the design assumes?
-
04
Are there any single points of failure that were accepted deliberately, and is that acceptance written down anywhere?
The failure behavior itself
-
05
You have two 10-gig uplinks. If one fails, does the remaining link carry peak load — or peak load plus whatever the failed link was carrying?
This is the most commonly missed calculation in the industry. Redundancy at 60% utilization per link is not redundancy.
-
06
When the peer link between an MLAG or vPC pair fails, what happens to orphan ports?
-
07
Which failure scenarios have been physically exercised in the last twelve months, and which have only been reasoned about?
-
08
What is the measured reconvergence time, and who measured it?
Gateways and the traffic path
-
09
For each segment, which device is actively forwarding as the default gateway right now — not which one is configured as primary?
-
10
Does first-hop redundancy preemption behave the way the team expects after a device recovers?
-
11
When traffic moves between tiers, does it take the path the design intends, or a path that happens to work?
-
12
If an inspection device is in that path, does return traffic take the same path?
Asymmetry after an inspection device is inserted is one of the most common causes of intermittent, unreproducible application faults.
Operational reality
-
13
What software versions are running, and which of them are past their support date?
-
14
If the two people who understand this fabric were both unavailable, could a competent engineer operate it from what is written down?
-
15
When was the failover procedure last read by somebody who then followed it, rather than skimmed?
-
16
Is there a rollback for every change you would make during a failure, and has it been tested?
Reading your score
Count the questions nobody could answer from evidence.
| Unanswered | What it means |
|---|---|
| 0 – 2 unknown | A well-held environment. The remaining gaps are worth closing, but nothing here is urgent. Re-run this annually and after any major change. |
| 3 – 5 unknown | Normal for a working estate. The risk is not the gaps themselves but that nobody is tracking which ones are open. Write them down and give each an owner. |
| 6 – 10 unknown | The documented environment and the running environment have drifted. This is the most common position and the most expensive one, because decisions are being made against a picture that is no longer accurate. |
| More than 10 unknown | This is not a documentation problem, it is a risk position. Any significant change — a refresh, a migration, an audit, an incident — will surface these in the worst possible circumstances. |
One caveat worth stating. A high count is not a failure of your team. It is what happens to every estate that has been operated under time pressure for a few years, by people doing their jobs correctly. The failure would be knowing the number and doing nothing with it.
If the number was uncomfortable.
The engagement that answers these
Establishes the real failure behavior of the fabric, gateways and redundancy mechanisms — as distinct from the documented behavior.
The capability area
Resiliency, failover, modernization and infrastructure assessment.
More self-assessments
Data center, routing, firewall policy, application delivery, access control, wireless, AWS, Azure, GCP, hybrid connectivity and automation.
Send us your number.
Tell us which questions you could not answer. We will tell you which of them actually matter in your situation, and which can wait — including when the answer is that none of this needs us.