Home/Self-assessments/Hybrid Connectivity
Cloud Networking · self-assessmentIs your on-premises to cloud connectivity actually resilient?
Sixteen questions on circuits, gateways, tunnels, routing exchange and whether the failover between them has ever been exercised.
Hybrid connectivity is usually built once, during a migration, by people who were under time pressure. It then becomes load-bearing for the entire estate and is rarely revisited until it fails.
These questions cover the paths joining your data center to your cloud environments, and what each does when it breaks.
How to use this. Go through the 16 questions with the team who run the environment. For each one, mark it only if somebody can answer it from evidence today — not from memory, not from a diagram, and not from what was true at build time. Count the ones you cannot. That number is the result.
The paths themselves
-
01
Can you list every circuit, gateway and tunnel connecting on-premises to cloud, with the provider and the term for each?
-
02
Where two paths are described as diverse, is that diversity verified at the physical layer or assumed from the contract?
Two circuits from two providers frequently share a duct. The word on the order form is not evidence.
-
03
Are your gateways themselves redundant, or is one device carrying a redundant pair of circuits?
-
04
What is the bandwidth of each path against measured peak, not provisioned capacity?
Routing exchange
-
05
What routes are advertised in each direction, and does either side apply filtering?
-
06
Are you near any route limit on the cloud side, and does anything alert before you reach it?
-
07
If both paths are up, is traffic using the one you intend, and why?
-
08
Does the routing design produce asymmetry between outbound and return traffic anywhere?
Failure behavior
-
09
If the primary path fails, how long before traffic recovers, and who measured that?
-
10
Has that failover been tested by actually failing the path, or only by reasoning about the configuration?
-
11
During failover, does the backup path have the capacity for full production load?
-
12
What monitoring would tell you a redundant path has failed while the primary is still up?
A silently failed backup path is a redundancy design that exists only on paper, and it is extremely common.
Security and lifecycle
-
13
Is traffic across each path encrypted, and where it is not, was that deliberate?
-
14
When do the contracts renew, and does anybody own that date?
-
15
Are the pre-shared keys and certificates on these tunnels tracked with expiry dates?
-
16
Does this design depend on any single account, credential or individual?
Reading your score
Count the questions nobody could answer from evidence.
| Unanswered | What it means |
|---|---|
| 0 – 2 unknown | A well-held environment. The remaining gaps are worth closing, but nothing here is urgent. Re-run this annually and after any major change. |
| 3 – 5 unknown | Normal for a working estate. The risk is not the gaps themselves but that nobody is tracking which ones are open. Write them down and give each an owner. |
| 6 – 10 unknown | The documented environment and the running environment have drifted. This is the most common position and the most expensive one, because decisions are being made against a picture that is no longer accurate. |
| More than 10 unknown | This is not a documentation problem, it is a risk position. Any significant change — a refresh, a migration, an audit, an incident — will surface these in the worst possible circumstances. |
One caveat worth stating. A high count is not a failure of your team. It is what happens to every estate that has been operated under time pressure for a few years, by people doing their jobs correctly. The failure would be knowing the number and doing nothing with it.
If the number was uncomfortable.
The engagement that answers these
Covers the circuits, gateways and tunnels joining the on-premises estate to cloud, and their behavior on failure.
The capability area
AWS, Azure and GCP connectivity, security, hybrid architecture and migration.
More self-assessments
Data center, routing, firewall policy, application delivery, access control, wireless, AWS, Azure, GCP, hybrid connectivity and automation.
Send us your number.
Tell us which questions you could not answer. We will tell you which of them actually matter in your situation, and which can wait — including when the answer is that none of this needs us.